Resource Type

Journal Article 2

Year

2020 1

2008 1

Keywords

Detection 1

Human noroviruses 1

Primer 1

Probe 1

RT-qPCR 1

Redesign 1

contouring technique 1

different 1

high-performance compressor 1

numerical 1

off-design 1

open ︾

Search scope:

排序: Display mode:

Application of high-turning bowed compressor stator to redesign of highly loaded fan stage

LI Shaobin, SU Jiexian, WANG Zhongqi

Frontiers in Energy 2008, Volume 2, Issue 4,   Pages 534-540 doi: 10.1007/s11708-008-0066-6

Abstract: A redesign of a highly loaded fan stage by using high-turning bowed compressor stator was conducted.

Keywords: off-design     different     numerical     contouring technique     high-performance compressor    

Redesigned Duplex RT-qPCR for the Detection of GI and GII Human Noroviruses Article

Danlei Liu, Zilei Zhang, Qingping Wu, Peng Tian, Haoran Geng, Ting Xu, Dapeng Wang

Engineering 2020, Volume 6, Issue 4,   Pages 442-448 doi: 10.1016/j.eng.2019.08.018

Abstract:

Human noroviruses (HuNoVs) are major foodborne pathogens that cause nonbacterial acute gastroenteritis worldwide. As the tissue-culture system for HuNoVs is not mature enough for routine detection of the virus, detection is mainly dependent on molecular approaches such as reverse transcription polymerase chain reaction (RT-PCR) and reverse transcription quantitative real-time polymerase chain reaction (RT-qPCR). The widely used primers and probes for RT-qPCR were established in the early 2000s. As HuNoVs are highly variant viruses, viral genome mutations result in previously designed primers and/or probes that were perfectly matched working less efficiently over time. In this study, a new duplex RT-qPCR (ND-RT-qPCR) was designed for the detection of genogroup I (GI) and genogroup II (GII) HuNoVs based on an analysis of viral sequences added in the database after 2010. Using long transcribed viral RNAs, the results demonstrate that the sensitivity of ND-RT-qPCR is as low as one genomic copy for both GI and GII HuNoVs. The performance of ND-RT-qPCR was further evaluated by a comparison with the commonly used Kageyama primer-probe sets for RT-qPCR (Kageyama RT-qPCR) for 23 HuNoV-positive clinical samples. All five GI samples were registered as positive by ND-RT-qPCR, whereas only two samples were registered as positive by Kageyama RT-qPCR. All 18 GII samples were registered as positive by ND-RT-qPCR, while 17 samples were registered as positive by Kageyama RT-qPCR. The sensitivity reflected by the Cq value was lower in ND-RT-qPCR than in Kageyama RT-qPCR. Our data suggest that ND-RT-qPCR could be a good fit for the detection of current strains of HuNoVs.

Keywords: Human noroviruses     RT-qPCR     Redesign     Primer     Probe     Detection    

Title Author Date Type Operation

Application of high-turning bowed compressor stator to redesign of highly loaded fan stage

LI Shaobin, SU Jiexian, WANG Zhongqi

Journal Article

Redesigned Duplex RT-qPCR for the Detection of GI and GII Human Noroviruses

Danlei Liu, Zilei Zhang, Qingping Wu, Peng Tian, Haoran Geng, Ting Xu, Dapeng Wang

Journal Article